InitializeTestSuite |
INFO Microsoft Windows XP (Build 2600)
INFO Service Pack 2.0
INFO USBCommandVerifier.dll ver 1.3.0.3
INFO TestServices.dll ver 1.3.0.3
INFO StackSwitcher.dll ver 1.3.0.3
|
MSC SerialNumberTest_DeviceAddressed | Passed |
INFO Now Starting Test:USB Mass Storage Serial Number Test (Configuration Index 0)
INFO Serial Number string for MSC device : iSerialNumber = 0x0
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Serial Number Test (Configuration Index 0):
Number of: Fails (0); Aborts (0); Warnings (0) ]
|
MSC SerialNumberTest_DeviceConfigured | Passed |
INFO Now Starting Test:USB Mass Storage Serial Number Test (Configuration Index 0)
INFO Serial Number string for MSC device : iSerialNumber = 0x0
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Serial Number Test (Configuration Index 0):
Number of: Fails (0); Aborts (0); Warnings (0) ]
|
MSC InterfaceDescriptorTest_DeviceAddressed | Failed |
INFO Now Starting Test:USB Mass Storage Interface Descriptor Test (Configuration Index 0)
INFO MSC Interface Class code = 0x8
INFO MSC Interface Sub Class code = 0x6
INFO MSC Interface Protocol code = 0x50
INFO Number of endpoints for MSC Interface = 2
INFO Serial Number string for MSC device : iSerialNumber = 0x0
ERROR Serial Number string is required for BOT device
FAIL (5.1.1) Device must have a serial number (if the device supports
a BOT interface, bInterfaceProtocol = 0x50).
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Interface Descriptor Test (Configuration Index 0):
Number of: Fails (1); Aborts (0); Warnings (0) ]
|
MSC InterfaceDescriptorTest_DeviceConfigured | Failed |
INFO Now Starting Test:USB Mass Storage Interface Descriptor Test (Configuration Index 0)
INFO MSC Interface Class code = 0x8
INFO MSC Interface Sub Class code = 0x6
INFO MSC Interface Protocol code = 0x50
INFO Number of endpoints for MSC Interface = 2
INFO Serial Number string for MSC device : iSerialNumber = 0x0
ERROR Serial Number string is required for BOT device
FAIL (5.1.1) Device must have a serial number (if the device supports
a BOT interface, bInterfaceProtocol = 0x50).
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Interface Descriptor Test (Configuration Index 0):
Number of: Fails (1); Aborts (0); Warnings (0) ]
|
MSC ClassRequestTest_DeviceConfigured | Aborted |
INFO Now Starting Test:USB Mass Storage Class Request Test (Configuration Index 0)
INFO Configuring device, set configuration = 0x1
INFO NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT User aborted tests!
INFO Re-enumerating device
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Class Request Test (Configuration Index 0):
Number of: Fails (0); Aborts (1); Warnings (0) ]
|
MSC ErrorRecoveryTest_DeviceConfigured | Aborted |
INFO Now Starting Test:USB Mass Storage Error Recovery Test (Configuration Index 0)
INFO Configuring device, set configuration = 0x1
INFO NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT User aborted tests!
INFO Re-enumerating device
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Error Recovery Test (Configuration Index 0):
Number of: Fails (0); Aborts (1); Warnings (0) ]
|
MSC CaseOneTest_DeviceConfigured | Aborted |
INFO Now Starting Test:USB Mass Storage Case One Test (Configuration Index 0)
INFO Configuring device, set configuration = 0x1
INFO NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT User aborted tests!
INFO Re-enumerating device
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Case One Test (Configuration Index 0):
Number of: Fails (0); Aborts (1); Warnings (0) ]
|
MSC CaseTwoTest_DeviceConfigured | Aborted |
INFO Now Starting Test:USB Mass Storage Case Two Test (Configuration Index 0)
INFO Configuring device, set configuration = 0x1
INFO NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT User aborted tests!
INFO Re-enumerating device
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Case Two Test (Configuration Index 0):
Number of: Fails (0); Aborts (1); Warnings (0) ]
|
MSC CaseThreeTest_DeviceConfigured | Aborted |
INFO Now Starting Test:USB Mass Storage Case Three Test (Configuration Index 0)
INFO Configuring device, set configuration = 0x1
INFO NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT User aborted tests!
INFO Re-enumerating device
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Case Three Test (Configuration Index 0):
Number of: Fails (0); Aborts (1); Warnings (0) ]
|
MSC CaseFourTest_DeviceConfigured | Aborted |
INFO Now Starting Test:USB Mass Storage Case Four Test (Configuration Index 0)
INFO Configuring device, set configuration = 0x1
INFO NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT User aborted tests!
INFO Re-enumerating device
INFO Unconfiguring the device
INFO Stopping Test [ USB Mass Storage Case Four Test (Configuration Index 0):
Number of: Fails (0); Aborts (1); Warnings (0) ]
|
MSC CompleteTests |
INFO **
INFO Device is NOT considered compliant with the Bootability specification.
INFO **
INFO Summary Log Counts [ Fails (2); Aborts (6); Warnings (0) ]
|