WORKSTATION: VLEERMUIS
DATE: Monday, November 26, 2007
TIME: 07:41:55 PM
OPERATOR: Anyone
NUMBER OF TESTS: 10
RESULT: failed


InitializeTestSuite
INFO    Microsoft Windows XP (Build 2600)
INFO    Service Pack 2.0
INFO    USBCommandVerifier.dll ver 1.3.0.3
INFO    TestServices.dll ver 1.3.0.3
INFO    StackSwitcher.dll ver 1.3.0.3
MSC SerialNumberTest_DeviceAddressedPassed
INFO    Now Starting Test:USB Mass Storage Serial Number Test (Configuration Index 0)
INFO    Serial Number string for MSC device : iSerialNumber = 0x0
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Serial Number Test (Configuration Index 0):
     Number of: Fails (0); Aborts (0); Warnings (0) ]
MSC SerialNumberTest_DeviceConfiguredPassed
INFO    Now Starting Test:USB Mass Storage Serial Number Test (Configuration Index 0)
INFO    Serial Number string for MSC device : iSerialNumber = 0x0
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Serial Number Test (Configuration Index 0):
     Number of: Fails (0); Aborts (0); Warnings (0) ]
MSC InterfaceDescriptorTest_DeviceAddressedFailed
INFO    Now Starting Test:USB Mass Storage Interface Descriptor Test (Configuration Index 0)
INFO    MSC Interface Class code = 0x8
INFO    MSC Interface Sub Class code = 0x6
INFO    MSC Interface Protocol code = 0x50
INFO    Number of endpoints for MSC Interface = 2
INFO    Serial Number string for MSC device : iSerialNumber = 0x0
ERROR   Serial Number string is required for BOT device
FAIL    (5.1.1) Device must have a serial number (if the device supports 
 a BOT interface, bInterfaceProtocol = 0x50).
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Interface Descriptor Test (Configuration Index 0):
     Number of: Fails (1); Aborts (0); Warnings (0) ]
MSC InterfaceDescriptorTest_DeviceConfiguredFailed
INFO    Now Starting Test:USB Mass Storage Interface Descriptor Test (Configuration Index 0)
INFO    MSC Interface Class code = 0x8
INFO    MSC Interface Sub Class code = 0x6
INFO    MSC Interface Protocol code = 0x50
INFO    Number of endpoints for MSC Interface = 2
INFO    Serial Number string for MSC device : iSerialNumber = 0x0
ERROR   Serial Number string is required for BOT device
FAIL    (5.1.1) Device must have a serial number (if the device supports 
 a BOT interface, bInterfaceProtocol = 0x50).
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Interface Descriptor Test (Configuration Index 0):
     Number of: Fails (1); Aborts (0); Warnings (0) ]
MSC ClassRequestTest_DeviceConfiguredAborted
INFO    Now Starting Test:USB Mass Storage Class Request Test (Configuration Index 0)
INFO    Configuring device, set configuration = 0x1
INFO    NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT   User aborted tests!
INFO    Re-enumerating device
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Class Request Test (Configuration Index 0):
     Number of: Fails (0); Aborts (1); Warnings (0) ]
MSC ErrorRecoveryTest_DeviceConfiguredAborted
INFO    Now Starting Test:USB Mass Storage Error Recovery Test (Configuration Index 0)
INFO    Configuring device, set configuration = 0x1
INFO    NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT   User aborted tests!
INFO    Re-enumerating device
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Error Recovery Test (Configuration Index 0):
     Number of: Fails (0); Aborts (1); Warnings (0) ]
MSC CaseOneTest_DeviceConfiguredAborted
INFO    Now Starting Test:USB Mass Storage Case One Test (Configuration Index 0)
INFO    Configuring device, set configuration = 0x1
INFO    NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT   User aborted tests!
INFO    Re-enumerating device
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Case One Test (Configuration Index 0):
     Number of: Fails (0); Aborts (1); Warnings (0) ]
MSC CaseTwoTest_DeviceConfiguredAborted
INFO    Now Starting Test:USB Mass Storage Case Two Test (Configuration Index 0)
INFO    Configuring device, set configuration = 0x1
INFO    NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT   User aborted tests!
INFO    Re-enumerating device
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Case Two Test (Configuration Index 0):
     Number of: Fails (0); Aborts (1); Warnings (0) ]
MSC CaseThreeTest_DeviceConfiguredAborted
INFO    Now Starting Test:USB Mass Storage Case Three Test (Configuration Index 0)
INFO    Configuring device, set configuration = 0x1
INFO    NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT   User aborted tests!
INFO    Re-enumerating device
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Case Three Test (Configuration Index 0):
     Number of: Fails (0); Aborts (1); Warnings (0) ]
MSC CaseFourTest_DeviceConfiguredAborted
INFO    Now Starting Test:USB Mass Storage Case Four Test (Configuration Index 0)
INFO    Configuring device, set configuration = 0x1
INFO    NOTE: It is expected the device has reset the data toggles on all Bulk endpoints after the above SetConfiguration call
ABORT   User aborted tests!
INFO    Re-enumerating device
INFO    Unconfiguring the device
INFO    Stopping Test [ USB Mass Storage Case Four Test (Configuration Index 0):
     Number of: Fails (0); Aborts (1); Warnings (0) ]
MSC CompleteTests
INFO    **
INFO    Device is NOT considered compliant with the Bootability specification.
INFO    **
INFO    Summary Log Counts [ Fails (2); Aborts (6); Warnings (0) ]