WORKSTATION: VLEERMUIS
DATE: Saturday, February 16, 2008
TIME: 09:52:10 PM
OPERATOR: Anyone
NUMBER OF TESTS: 13
RESULT: failed


InitializeTestSuite
INFO    Microsoft Windows XP (Build 2600)
INFO    Service Pack 2.0
INFO    USBCommandVerifier.dll ver 1.3.0.3
INFO    TestServices.dll ver 1.3.0.3
INFO    StackSwitcher.dll ver 1.3.0.3
DeviceDescriptorTest_DeviceConfiguredFailed
INFO    Now Starting Test:Device Descriptor Test (Configuration Index 0)
FAIL    (1.1.2) Devices must support being set to Addressed/Configured state.
INFO    Stopping Test [ Device Descriptor Test (Configuration Index 0):
     Number of: Fails (1); Aborts (0); Warnings (0) ]
DeviceDescriptorTest_DeviceAddressedPassed
INFO    Now Starting Test:Device Descriptor Test (Configuration Index 0)
INFO    Device descriptor length : 12
INFO    Device descriptor type : 1
INFO    Major version : 1
INFO    Minor version : 10
INFO    Each interface specifies its own device class type
INFO    Device sub class : 0
INFO    Device protocol : 0
INFO    Device MaxPacketSize0 : 40
ABORT   Create file on 'usb.if' failed
WARNING Failed to get vendor information for VendorID : 781
INFO    Device ProductID : 7421
INFO    Device BCD : 100
INFO    ENGLISH_US           language string descriptor is : Rockbox.org
INFO    ENGLISH_US           language string descriptor is : Rockbox media player
INFO    ENGLISH_US           language string descriptor is : 0000000000000000A4B4323508F212FD
INFO    Number of configurations device supports : 1
INFO    Stopping Test [ Device Descriptor Test (Configuration Index 0):
     Number of: Fails (0); Aborts (1); Warnings (1) ]
ConfigDescriptorTest_DeviceConfiguredFailed
INFO    Now Starting Test:Configuration Descriptor Test (Configuration Index 0)
FAIL    (1.1.2) Devices must support being set to Addressed/Configured state.
INFO    Stopping Test [ Configuration Descriptor Test (Configuration Index 0):
     Number of: Fails (1); Aborts (0); Warnings (0) ]
ConfigDescriptorTest_DeviceAddressedPassed
INFO    Now Starting Test:Configuration Descriptor Test (Configuration Index 0)
INFO    Number of interface descriptors found 1
INFO    Number of alternate interface descriptors found : 0
INFO    Number of endpoint descriptors found : 2
INFO    Configuration descriptor length : 9
INFO    Configuration descriptor type : 2
INFO    Configuration descriptor TotalLength : 20
INFO    Configuration descriptor NumInterfaces : 1
INFO    Configuration descriptor ConfigurationValue: 1
INFO    Configuration descriptor string descriptor index : 0
INFO    Configuration descriptor bmAttributes : c0
INFO    Device does not support remote wake up
INFO    Maximum power device requires : 500mA
INFO    Device is BUS/SELF-POWERED
INFO    Device is currently BUS POWERED
INFO    Currently remote wakeup is DISABLED
INFO    Stopping Test [ Configuration Descriptor Test (Configuration Index 0):
     Number of: Fails (0); Aborts (0); Warnings (0) ]
InterfaceDescriptorTestFailed
INFO    Now Starting Test:Interface Descriptor Test (Configuration Index 0)
FAIL    (1.1.2) Devices must support being set to Addressed/Configured state.
INFO    Stopping Test [ Interface Descriptor Test (Configuration Index 0):
     Number of: Fails (1); Aborts (0); Warnings (0) ]
EndpointDescriptorTest_DeviceConfiguredFailed
INFO    Now Starting Test:Endpoint Descriptor Test (Configuration Index 0)
FAIL    (1.1.2) Devices must support being set to Addressed/Configured state.
INFO    Stopping Test [ Endpoint Descriptor Test (Configuration Index 0):
     Number of: Fails (1); Aborts (0); Warnings (0) ]
EndpointDescriptorTest_DeviceAddressedPassed
INFO    Now Starting Test:Endpoint Descriptor Test (Configuration Index 0)
INFO    Testing Interface number : 0 Alternate setting : 0
INFO    Endpoint descriptor length : 7
INFO    Endpoint descriptor type : 5
INFO    Endpoint Type : Bulk, Number : 1, Direction : IN
INFO    Endpoint descriptor bmAttributes : 2
INFO    Endpoint descriptor raw MaxPacketSize : 10
INFO    Endpoint descriptor interval : 0
INFO    Endpoint descriptor length : 7
INFO    Endpoint descriptor type : 5
INFO    Endpoint Type : Bulk, Number : 1, Direction : OUT
INFO    Endpoint descriptor bmAttributes : 2
INFO    Endpoint descriptor raw MaxPacketSize : 10
INFO    Endpoint descriptor interval : 0
INFO    Stopping Test [ Endpoint Descriptor Test (Configuration Index 0):
     Number of: Fails (0); Aborts (0); Warnings (0) ]
HaltEndpointTestFailed
INFO    Now Starting Test:Halt Endpoint Test (Configuration Index 0)
INFO    Testing Interface number : 0 Alternate setting : 0
FAIL    (1.2.50) A device must support the GetInterface request if it has
 alternate settings for that interface.
INFO    Testing EndPoint type : Bulk, Address : 81
INFO    Endpoint is currently not halted
ERROR   Halt endpoint failed
ERROR   Endpoint could not be halted
INFO    Cleared endpoint halt
FAIL    (1.2.91) A device that has Bulk/Interrupt endpoints must support the
 Halt Endpoint request on those endpoints.
INFO    Testing EndPoint type : Bulk, Address : 1
INFO    Endpoint is currently not halted
ERROR   Halt endpoint failed
ERROR   Endpoint GetStatus request failed
ERROR   Clear endpoint halt failed
ERROR   Endpoint GetStatus request failed
FAIL    (1.2.91) A device that has Bulk/Interrupt endpoints must support the
 Halt Endpoint request on those endpoints.
INFO    Stopping Test [ Halt Endpoint Test (Configuration Index 0):
     Number of: Fails (3); Aborts (0); Warnings (0) ]
SetConfigurationTestFailed
INFO    Now Starting Test:SetConfiguration Test (Configuration Index 0)
ERROR   Get configuration descriptor failed for configuration index : 0
ERROR   Could not get configuration value for configuration index 0
FAIL    (1.1.1) Devices must have a corresponding configuration value for a 
 valid configuration index.
INFO    Stopping Test [ SetConfiguration Test (Configuration Index 0):
     Number of: Fails (1); Aborts (0); Warnings (0) ]
SuspendResumeTestAborted
INFO    Now Starting Test:Suspend/Resume Test (Configuration Index 0)
INFO    Suspended the parent port of the device
INFO    Get Device Descriptor failed after resuming device.
FAIL    (1.1.30) A suspended device must resume normal operation when resume 
 signaling is seen on its upstream port.
ERROR   CVHub_ReEnumerateAll::Could not find device under test after enumeration
ABORT   Couldn't reenumerate device.
INFO    Stopping Test [ Suspend/Resume Test (Configuration Index 0):
     Number of: Fails (1); Aborts (1); Warnings (0) ]
RemoteWakeupTestEnabledAborted
ABORT   Invalid arguments received
RemoteWakeupTestDisabledAborted
ABORT   Invalid arguments received
EnumerationTestAborted
ABORT   Invalid arguments received
DisplayOtherTestsToRun
ABORT   Invalid arguments received
Summary
INFO    Summary Log Counts [ Fails (9); Aborts (2); Warnings (1) ]